PC Connection
This DB-9 type connection is used to send and receive information to and from the computer
running the DriveWare™ software. Note: this connection is parallel with the DB-9 connection
on the rear panel.
Load Button
The load button is used to load the selected program.
Program Display
This program display is used to indicate the currently selected program of the 220i.
Program Up and Down (Filter Clear Ch1 and Ch2)
These program up and down buttons are used to scroll through the program menu of the 220i.
Pushing and holding these buttons will clear the live filters on these channels if there are AFS
modules in the signal path.
PC LED
This LED (when lit), indicates that the 220i is connected to the PC. When it is flashing, the 220i
is sending/receiving information from the PC.
CLIP LED
This LED (when lit), .indicates that a signal is clipping, either in the analog input section, or in
the DSP.
Input Meters
These meters monitor the signal level at the output of the A/D converter.
Threshold Meters
The threshold meters indicate indicate that the threshold level has been crossed within the out-
put dynamics section. The tri-color LED will be green when the signal is below the threshold
for a Compressor, Limiter and AGC, and above the threshold for the Gate. Yellow indicates
that the signal is in the over-easy region in the Compressor or Limiter and within the Window
of the AGC. Red indicates that the signal has passed over the threshold for the Compressor,
Limiter and AGC, or below the threshold for the Gate.
Output Meters
These meters monitor the signal level at the input of the D/A converter.