Dbx iEQ 31 User Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
13
iEQ User Manual
iEQ
Factory Hard Reset
In the event that you experience peculiar behavior with the iEQ or would like to set the Power-Up Mode
settings back to their factory default state, please perform the following Factory Hard Reset procedure:
• Power on the unit while pressing and holding the CHANNEL 2 <AFS> button until the
CHANNEL 2 meters display the LED pattern shown below, then release the button�
CHANNEL 2
Power Up Prompt
• Press and release the CHANNEL 1 <AFS> button until the CHANNEL 1 AFS button LED
is lit Yellow
• To perform the Hard Reset, press and hold the CHANNEL 2 <AFS> button until all
CHANNEL 2 meter LEDs begin to flash, then release�
• To exit and return to normal operating mode, press and hold the CHANNEL 1 <AFS>
button until all CHANNEL 1 meter LEDs begin to flash, then release� The unit will take a
few seconds to reboot and will then be ready to operate� All settings will now be back to their
factory default state�
The iEQ’s factory default settings are as follows:
Power-Up Mode Menu Default Setting
System Lockout Unlocked
Live Filter Lift Time Live Filter Lift Off
AFS Normal vs� 6-Fixed/6-Live Mode AFS Normal Mode